contact@mcqsbase.com
Practice Makes Perfect
McqsBase
Your Exam Prep Partner
Home
MCQs
Quiz
Past Papers
Past Interviews
Mock Tests
Submit
About
Blog
Contact
Loading MCQs…
Home
›
MCQs
›
Mechanical Engineering
Home
/
MCQs
/
Mechanical Engineering
Mechanical Engineering MCQs (Page 59)
Quiz Mode
581
In refrigerators, the temperature difference between the evaporating refrigerant and the medium being cooled should be_________________?
A
high, of the order of 25°
B
as low as possible (3 to 11°C)
C
zero
D
any value
E
none of the above
By: Admin
Correct
View Full Question →
582
In a flooded evaporator refrigerator, an accumulator at suction of compressor is used to___________________?
A
collect liquid refrigerant and prevent it from going to compressor
B
detect liquid in vapour
C
superheat the vapour
D
collect vapours
E
increase refrigeration effect
By: Admin
Correct
View Full Question →
583
Accumulators should have adequate volume to store refrigerant charge at least_________________?
A
10%
B
25%
C
50%
D
75%
E
100%
By: Admin
Correct
View Full Question →
584
A refrigeration cycle operates between condenser temperature of + 27°C and evaporator temperature of- 23°C. The Cannot coefficient of performance of cycle will be_________________?
A
0.2
B
1.2
C
5
D
6
E
10
By: Admin
Correct
View Full Question →
585
In vapor compression refrigeration system, refrigerant occurs as liquid between_________________?
A
condenser and expansion valve
B
compressor and evaporator
C
expansion valve and evaporator
D
compressor and condenser
E
none of the above
By: Admin
Correct
View Full Question →
586
Efficiency of a Carnot engine is given as 80%. If the- cycle direction be reversed, what will be the value of COP of reversed Carnot cycle_________________?
A
1.25
B
0.8
C
0.5
D
0.25
E
none of the above
By: Admin
Correct
View Full Question →
587
Aqua ammonia is used as refrigerant in the following type of refrigeration system_________________?
A
compression
B
direct
C
indirect
D
absorption
E
none of the above
By: Admin
Correct
View Full Question →
588
If a heat pump cycle operates between the condenser temperature of +27°C and evaporator temperature of – 23°C, then the Carnot COP will be_________________?
A
0.2
B
1.2
C
5
D
6
E
10
By: Admin
Correct
View Full Question →
589
In a refrigeration cycle, the flow of refrigerant is controlled by___________________?
A
compressor
B
condenser
C
evaporator
D
expansion valve
E
all of the above
By: Admin
Correct
View Full Question →
590
The lower horizontal line of the refrigeration cycle plotted on pressure-enthalpy-diagram represents_____________________?
A
condensation of the refrigerant vapour
B
evaporation of the refrigerant liquid
C
compression of the refrigerant vapour
D
metering of the refrigerant liquid
E
none of the above
By: Admin
Correct
View Full Question →
‹
1
...
58
59
60
...
213
›
GO
MCQs Categories
MAIN MCQS MENU
Accounting Mcqs
Auditing Mcqs
Biology Mcqs
Chemistry Mcqs
Computer Mcqs
English Mcqs
Everyday Science Mcqs
Finance Mcqs
General Knowledge MCQs
HRM Mcqs
Islamic Studies Mcqs
Management Sciences
Marketing Mcqs
Maths Mcqs
Pak Study Mcqs
Pakistan Current Affairs MCQs
Pedagogy Mcqs
Physics Mcqs
URDU Mcqs
World Current Affairs MCQs
ENGINEERING MCQS
Chemical Engineering Mcqs
Civil Engineering Mcqs
Electrical Engineering Mcqs
Mechanical Engineering Mcqs
Software Engineering Mcqs
MEDICAL SUBJECTS
Biochemistry
Dental Materials
General Anatomy Mcqs
Medical Mcqs
Microbiology
Oral Anatomy
Oral Histology
Oral Pathology and Medicine
Pathology
Pharmacology
Physiology Mcqs
OTHER SUBJECTS
Agriculture Mcqs
Economics Mcqs
English Literature Mcqs
Forestry Mcqs
International Relations Mcqs
Judiciary And Law Mcqs
Physical Education Mcqs
Political Science Mcqs
Psychology Mcqs
Sociology Mcqs
Statistics Mcqs
SUBMIT MCQS
Submit Mcqs
QUIZ MENU
Computer Online Quiz
Everyday Science Quiz
General Knowledge Quiz
Islamic Studies Mcqs Quiz
Pakistan Studies Quiz
ELECTION OFFICER
Election Officer Mcqs
Previous questions
Next questions